Skip to content

ORNO 3-phase electricity meter, 80A, MID, 3 modules, DIN TH-35mm

by Orno
Original price €86,76 - Original price €86,76
Original price
€86,76
€86,76 - €86,76
Current price €86,76
SKU DGT0410183
Ships within 7 business days Please note that quantities are limited and dynamic. At the time of ordering, the item may be out of stock. We will notify you in a timely manner in the event that we are unable to fulfill the order.

Избери период за изплащане и виж месечната вноска

Месечна вноска Обща сума за плащане ГПР Лихва Банка

Description

Three-phase electricity meter ORNO OR-WE-520, 80A, Single-tariff, MID certificate. The model is ideal for monitoring energy consumption for household purposes. A digital three-phase meter for direct measurement of active energy.

– Type: digital;
– Type: AC three-phase;
– Single-tariff;
– Power supply: 3x230V/400V AC, 50/60Hz;
– Maximum permissible current of 80A;
– Meter constant: 800 imp/kWh;
– Display: LCD (number of digits 6+2 = 000,000.00 kWh);
– Degree of protection: IP51;
– DIN rail mounting: 35mm;
– Modules: 4.5;
– Operating temperature: -25 to +45 degrees;
– Dimensions: 76 / 116.5 / 65 mm;
Product number: ORNO OR-WE-520
EAN: 5900378653011
Packaging: yes
Gross weight: 0.550 g
Net weight: 0.520 g
Manufacturer: ORNO Poland
Warranty: 24 months
Package contents: box of 1 piece

What should we know about the electricity meter?
The electricity meter is the device on which the accurate and correct calculation of our electricity bill depends. Despite this undeniable fact, few people consider it important and necessary to check it regularly and to know what it measures and how. We present to you basic guidelines on where to start and how to orient yourself quickly and easily in the technical part of consumer electricity distribution.
There are many types of electricity meters, each electricity distribution company uses different devices, so a characteristic of one unified model cannot be given.

The electricity meter must show:
- the total value of energy consumed (kWh)
- day tariff (marked T2) / night tariff (marked T1)
- clock / date
- direction of energy
- in case of a possible error, displays the symbol F

The data on the display change periodically every few seconds and show the different values, respectively for the day and night tariff.
The displays of different electricity suppliers have different characteristics and designations, but they have several basic indicators that appear. The meaning of each designation is explained on the electricity meter's box, where there is a plate with technical data.

Clock in electricity meters:
In pre-electronic electricity meters, the clock depends on the internal battery built into the device. It often happens that the clock disappears, which can occur for various reasons – it has been without power for some time or a problem has occurred when connecting it to the energy source. As a result of the malfunction, the electricity meter starts to accumulate only on one tariff. It turns out that when the clock does not record and disappears, the bill starts to accumulate at the expense of the company, i.e. in the higher tariff. In case of such a problem, you should immediately notify the supplier company, as the clock cannot be set by the user.

How can we check whether the electricity meter is accumulating and whether someone is misusing it at our expense?
On the electrical panel, the user has access to a circuit breaker after the electricity meter, which can be switched off. Through it, it can be established whether someone has illegally connected to their supply. If you switch off the circuit breaker but the electricity meter continues to charge for energy, then something is wrong and someone else is using your electricity.

How long is the life of an electricity meter?
On average, electricity meters are replaced or undergo metrological verification every 7 years. The metrological characteristics of electricity meters are checked by measurement companies and laboratories.

What can the user do if there are doubts that the electricity meter is not recording correctly?
The user has the right to request that the electricity meter be checked. When such a request is made, the electricity meter goes to the Directorate of Measures and Measuring Instruments of the National Centre of Metrology, where it is checked whether it is fit for use or not. This procedure takes between one week and a month, and during this time the electricity distribution company may install another measuring device, which is also a way to establish a fault.

Also, anyone can install their own internal electricity meter, which they use for personal needs, to record the consumption of individual groups of appliances and to be aware of their consumption. It is good to have a control meter and compare the data with the external one. The difference between the two should not be large, no more than 2%.

Display:
Consumers should regularly monitor the indicators on their electricity meter's display and watch for deviations.
Clock. Monitor the accuracy of the clock and the date. Besides hours, electricity meters are also programmed by days of the week.

Tariff:
Monitor whether the night and day tariffs switch appropriately according to the time of day and whether only one tariff is accumulating. This can also be established from the received billing statement.

Periods:
If you notice a significant difference in accumulated consumption between the current and previous month, report it immediately.

Bills:
Check every bill to be sure of your meter's regularity.

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare