Description
MAGUS Metal D630 BD metallurgical digital microscope for observation by bright-field, dark-field and polarised light microscopy methods. The powerful halogen illumination produces a quality image with every objective and every microscopy method. The microscope is designed for quality control and the study of the microstructure of metallic and semiconductor materials, as well as opaque objects. It is used for research in production plants, in laboratories of research centres and in university faculties.
Digital camera
The MAGUS CLM30 digital camera is designed for microscopy by the bright-field and dark-field methods.
The camera is equipped with an 8.3 MP sensor and produces realistic images with a resolution of 3840x2160 px. It is recommended to use the camera with objectives of 4x, 10x, 20x and 40x magnification. When working with low-magnification objectives, the camera will allow you to see finer details.
Video is recorded at 45 fps or 70 fps depending on the resolution: they are smooth, with soft and fine transitions between frames. The movement of the sample is displayed in real time without delay. The camera makes it easier to work with moving objects and is suitable for classroom demonstrations.
The camera is fitted with a USB 3.0 interface. The data transfer speed is 10 times higher than that of cameras with USB 2.0. The high-speed camera is recommended for professional laboratories, research or university teaching.
Optics
The trinocular head has a trinocular tube in which a digital camera is mounted (not included). The light beam is directed to the eyepieces or to the trinocular tube by the eyepiece/camera light-path selection button. The trinocular head is inclined at 30° for easy observation. The dioptre adjustment ring is located on the left tube.
After the supplied objectives are mounted in the revolving nosepiece, one slot remains free for an additional objective. All basic objectives are plan achromatic with a long focal distance and are suitable for bright-field and dark-field microscopy.
Illumination
For dark-field observations the microscope is equipped with a halogen bulb of increased power (50 W). The reflected-light illumination system additionally includes: a set of filters, an aperture diaphragm and a field diaphragm, a device for dark-field work, a built-in analyser and a removable polariser. The apertures and the light source can be centred. Köhler illumination can be adjusted.
Specimen stage and focusing mechanism
The microscope has an interesting design of the stand and focusing mechanism – the specimen can be of any size and height. Another feature is its small size – the microscope can be easily placed on surfaces with a maximum height of 40 cm. The coarse and fine focus knobs are coaxial and are located on both sides of the microscope body. The tension of the coarse focus adjustment can also be regulated.
Accessories
Additional accessories for the MAGUS Metal 630 BD microscope can be ordered separately. They include compatible eyepieces, long focal distance objectives for bright-field and dark-field work, calibration specimens and digital cameras.
Main features of the microscope:
- Suitable for studying opaque specimens of any size and height
- Trinocular head with a trinocular tube for mounting a digital camera and with a beam splitter 100/0 and 0/100
- Reflected-light observations by the bright-field, dark-field and polarised light microscopy methods
- The power of the halogen light source is increased to 50 W (suitable for dark-field study)
- Field diaphragm and aperture diaphragm for Köhler illumination, as well as a set of coloured light filters, centring of both diaphragms and the light source
- Compact stand design for mounting the microscope in small spaces
- Large set of additional accessories
Main features of the camera:
- For microscopic observations by the bright-field method with 4x, 10x, 20x and 40x objectives
- Resolution 8.3 MP: when working with low-magnification objectives, the camera will allow you to see finer details
- 45 fps and 70 fps at resolutions of 3840x2160 px and 1920x1080 px for observing moving specimens, video recordings and movement of samples without flicker or delay
- The Peltier element lowers the sensor temperature during prolonged operation and removes thermal noise. Therefore, low shutter speeds can be used during photography.
- The SONY Exmor back-illuminated colour CMOS sensor provides low noise and high light sensitivity even in low light. You will get clearer and brighter images with more saturated colours.
- USB 3.0 interface for fast and smooth data transfer
- Software for photo recording, video recording, editing, external display functions, linear and angular measurements
The kit includes:
- The MAGUS CLM30 digital camera (digital camera, USB cable, adapter for 12 V, 3 A, case, installation CDs with drivers and software, user manual and warranty card)
- Stand with focusing mechanism, specimen stage and revolving nosepiece
- Reflected-light illuminator with illuminator housing
- Trinocular head
- Plan achromatic objective with infinity correction: PL L5x/0.12 BD WD 9.7 mm
- Plan achromatic objective with infinity correction: PL L10x/0.25 BD WD 9.3 mm
- Plan achromatic objective with infinity correction: PL L20x/0.40 BD WD 7.2 mm
- Plan achromatic objective with infinity correction: PL L50x/0.70 BD WD 2.5 mm
- 10x/22 mm eyepiece with extra-long eye relief (2 pcs)
- C-mount adapter 1x
- Hex key
- Base with power input
- Power cable
- Power cable for the reflected-light illuminator
- Dust cover
- User manual and warranty card
Available on request:
- 10x/22 mm eyepiece with scale
- 12.5x/14 mm eyepiece (2 pcs)
- 15x/15 mm eyepiece (2 pcs)
- 20x/12 mm eyepiece (2 pcs)
- 25x/9 mm eyepiece (2 pcs)
- Plan achromatic objective with infinity correction: PL L40x/0.60 BD WD 3.0 mm
- Plan achromatic objective with infinity correction: PL L60x/0.70 BD WD 1.9 mm
- Plan achromatic objective with infinity correction: PL L80x/0.80 BD WD 0.8 mm
- Plan achromatic objective with infinity correction: PL L100x/0.85 (dry) BD WD 0.4 mm
- Calibration specimen
Specifications
| Warranty | 5 years |
|---|---|
| Packaging dimensions (L x W x H) | 39x37x73 cm |
| Shipping weight | 22.3 kg |
| Type | metallurgical, light/optical |
| Microscope head type | trinocular |
| Head | Siedentopf |
| Head inclination angle | 30 ° |
| Magnification, x | 50 — 500 |
| Magnification range | from 200x to 800x |
| Magnification, x (option) | 50–1000/1250/1500/2000/2500 |
| Eyepiece tube diameter, mm | 30 |
| Eyepieces | 10x/22 mm, eye relief: 10 mm (*option: 10x/22 mm with scale, 12.5x/14; 15x/15; 20x/12; 25x/9) |
| Objectives | planachromatic with infinity correction: PL L5x/0.12 BD, PL L10x/0.25 BD, PL L20x/0.40 BD, PL L50x/0.70 BD; parfocal distance 45 mm (*option: PL L40x/0.60 BD, PL L60x/0.70 BD, PL L80x/0.80 BD, PL L100x/0.85 BD (dry)) |
| Revolving nosepiece | for 5 objectives |
| Working distance, mm | 9.7 (5x); 9.3 (10x); 7.2 (20x); 2.5 (50x); 3.0 (40x); 1.9 (60x); 0.80 (80x); 0.40 (100x) |
| Interpupillary distance, mm | 48 — 75 |
| Stage size, mm | 185x140 |
| Stage travel range, mm | 35/30 |
| Stage characteristics | biaxial mechanical; microscope base size: 300x240 mm |
| Eyepiece diopter adjustment, dioptres | ±5 (on left tube) |
| Diaphragm | built-in aperture and field |
| Focusing | coaxial, coarse (with coarse focus mechanism tension adjustment) and fine (0.002 mm) |
| Body | aluminium alloy |
| Illumination | halogen |
| Brightness adjustment | yes |
| Power supply | 220±22 V, 50 Hz, AC mains |
| Light source type | 12 V/50 W |
| Light filters | green, blue, yellow, frosted |
| Operating temperature range, °C | 5 — 35 |
| Additional | built-in removable analyser and polariser, darkfield examination device |
| User level | for professionals, experienced users |
| Assembly and installation difficulty level | complex |
| Application | metallurgical |
| Illumination position | upper |
| Examination method | bright field, polarization, dark field |
| Bag/case/pouch included | dust cover |
| Sensor | SONY Exmor CMOS |
| Colour/monochrome | colour |
| Megapixels | 8.3 |
| Maximum resolution, pixels | 3840x2160 |
| Sensor size | 1/1,2'' (11,14x6,26 mm) |
| Pixel size, μm | 2.9x2.9 |
| Two-stage thermoelectric module (Peltier element) that sets the temperature 42°C below room temperature | yes |
| Light sensitivity | 5970 mV at 1/30 s |
| Signal-to-noise ratio | 0.15 mV at 1/30 s |
| Exposure time | 0.1 ms – 1 h |
| Video recording | yes |
| Frame rate, fps at resolution | 45 at 3840x2160, 70 at 1920x1080 |
| Digital ADC bit depth (bits) | 8/12 (selectable) |
| Mounting location | trinocular tube |
| Image format | *.jpg, *.bmp, *.png, *.tif |
| Video format | output: *.wmv, *.avi, *.h264 (Windows 8 and newer), *h265 (Windows 10 and newer) |
| Spectral range, nm | 380–650 (built-in infrared filter) |
| Shutter type | ERS (electronic rolling shutter) |
| White balance | automatic, manual |
| Exposure control | automatic, manual |
| Software features | exposure time, image size, brightness |
| Software | MAGUS View |
| Output | 5 Gb/s, USB 3.0 |
| System requirements | Windows 8/10/11 (32-bit and 64-bit), Mac OS X, Linux, up to 2.8 GHz Intel Core 2 or more powerful, at least 2 GB RAM, USB 3.0 port, CD-ROM, 17" or larger display |
| Mounting type | C-shaped mount |
| Camera power supply | DC, 5 V, from USB computer port; adapter for 12 V, 3 A for powering the Peltier element |
| Camera operating temperature range, °C | -10 — 50 |
| Operating humidity range, % | 30 — 80 |